Archived posting to the Leica Users Group, 2007/05/21

[Author Prev] [Author Next] [Thread Prev] [Thread Next] [Author Index] [Topic Index] [Home] [Search]

Subject: [Leica] Visoflex_less Experiment
From: chs2018 at med.cornell.edu (Chris Saganich)
Date: Mon May 21 12:52:47 2007
References: <26773355-19E7-45BC-AD9D-EE8985C3BFAC@comcast.net> <6.2.1.2.2.20070521120351.05249418@pop.med.cornell.edu> <E0A1FFD6-B8E6-4A42-B143-3DBE3E4389EE@comcast.net>

...and expensive as far as adaptors go.  B&H wants $250 for a 14167 !!


At 01:23 PM 5/21/2007, you wrote:
>If you have all the pieces you're in good shape. The hardest parts to
>find are the R to Viso (M) 14167 adapter and the 65mm lens. The rest
>is pretty common including the Universal focusing mount 16464.
>
>Len
>
>
>On May 21, 2007, at 12:05 PM, Chris Saganich wrote:
>
>>Thanks for sharing.  This is good information that I can actually
>>put to use!  Canon EOS and Elmar 65 may be a good combo indeed.
>>Chris
>>
>>At 02:33 PM 5/19/2007, you wrote:
>>>This is an experiment I just thought of this morning. I have a pretty
>>>good assortment of Visoflex stuff and thought I might have enough
>>>stuff to use my Canon 20D in place of the Visoflex housing.
>>>
>>>Here is the photo.
>>>
>>>http://tinyurl.com/2ajwaj
>>>
>>>And here is the photo of what it was taken with.
>>>
>>>http://tinyurl.com/ytmdvs
>>>
>>>For those of you who are interested this is the equipment.
>>>
>>>
>>>20D -> Novoflex EOS to R adapter -> Leica R to Viso adapter ->
>>>Bellows II -> UOOYW adapter -> UOOVH adapter -> 135mm Hektor lens
>>>head.
>>>
>>>This setup focuses from macro to infinity. It will also accept the
>>>65mm Elmar and Universal Focusing mount (bellows not needed).
>>>
>>>Len
>>>
>>>
>>>
>>>
>>>
>>>_______________________________________________
>>>Leica Users Group.
>>>See http://leica-users.org/mailman/listinfo/lug for more information
>>
>>Chris Saganich, Sr. Physicist
>>Weill Medical College of Cornell University
>>New York Presbyterian Hospital
>>chs2018@med.cornell.edu
>>Ph. 212.746.6964
>>Fax. 212.746.4800
>>Office A-0049
>>
>>
>>_______________________________________________
>>Leica Users Group.
>>See http://leica-users.org/mailman/listinfo/lug for more information
>
>
>_______________________________________________
>Leica Users Group.
>See http://leica-users.org/mailman/listinfo/lug for more information

Chris Saganich, Sr. Physicist
Weill Medical College of Cornell University
New York Presbyterian Hospital
chs2018@med.cornell.edu
Ph. 212.746.6964
Fax. 212.746.4800
Office A-0049 



In reply to: Message from len-1 at comcast.net (Leonard Taupier) ([Leica] Visoflex_less Experiment)
Message from chs2018 at med.cornell.edu (Chris Saganich) ([Leica] Visoflex_less Experiment)
Message from len-1 at comcast.net (Leonard Taupier) ([Leica] Visoflex_less Experiment)