Archived posting to the Leica Users Group, 1999/10/31
[Author Prev] [Author Next] [Thread Prev] [Thread Next] [Author Index] [Topic Index] [Home] [Search]Hi Noel, THis is fairly easy to perform yourself. You need a small jewelers screwdirver. Remove the (shiny screw head) dust cover located above the lens mount in the 12 o'clock postion. Insert the screwdriver into the hole. While looking thru the rangefinder, adjust the screw until the two images coincide vertically. It only takes a slight bit of adjustment. THis should take you only a few minutes. When you're done return the dust cap. Bill