Archived posting to the Leica Users Group, 2002/05/02
[Author Prev] [Author Next] [Thread Prev] [Thread Next] [Author Index] [Topic Index] [Home] [Search]If you run a nozzle check and have no flaws you have real problems. But if you have a blocked print head,run the cleaning program several times, it intensifies each time you run it. If that doesn't work, push the cartridge changing button to move the print head over, after it starts to move unplug the unit (this will keep the print head from locking in the closed position). Fold some paper towel and put it on the area where the print head passes, spray windex on the towel and manually move the print head over the towel several times, then preform a nozzle check. Learned this one from Jon Cone. Roy Feldman Ford Photographic rfeldma1@ford.com - -- To unsubscribe, see http://mejac.palo-alto.ca.us/leica-users/unsub.html