Subject: [Leica] Re:IIIc Baseplate / Bruce
From: Leikon35 <Leikon35@aol.com>
Date: Sun, 8 Mar 1998 21:20:39 EST

>>
 Bruce,
 The guide bar on the IIIf prevents its use on the IIIc but remove 
 both base plates & compare the relative positions of the locking disc.
 If the one on the C is in a different position, remove the screw & just
 change it to match that of the one that works.

 Marvin Moss
======================================================
In a message dated 98-03-08 19:37:58 EST, Bruce wrote:
<< 
 I have a pair of screw-mount Leicas: a IIIc and a IIIf.  I've had the IIIc
for about
 25 years, and there's a minor problem with it that's been irritating me for
the
 duration.  Its baseplate is only locked closed if I lock it half-way -- in
other
 words, between what should be the open and closed settings.  There's no
obvious sign
 of damage, but if I try to lock it all the way, it pops open just as easily
as if
 it's set to the open position.
 
 Has anyone seen anything like this?  Weird!
 
 Bruce