[Author Prev] [Author Next] [Thread Prev] [Thread Next] [Author Index] [Topic Index] [Home] [Search]>> Bruce, The guide bar on the IIIf prevents its use on the IIIc but remove both base plates & compare the relative positions of the locking disc. If the one on the C is in a different position, remove the screw & just change it to match that of the one that works. Marvin Moss ====================================================== In a message dated 98-03-08 19:37:58 EST, Bruce wrote: << I have a pair of screw-mount Leicas: a IIIc and a IIIf. I've had the IIIc for about 25 years, and there's a minor problem with it that's been irritating me for the duration. Its baseplate is only locked closed if I lock it half-way -- in other words, between what should be the open and closed settings. There's no obvious sign of damage, but if I try to lock it all the way, it pops open just as easily as if it's set to the open position. Has anyone seen anything like this? Weird! Bruce